Specifications
Appendix D Supervision Terminal Commands Installation and Operation Manual
D-2 Commands FCD-E1LC Ver. 1.0
D.2 Commands
BYE
Purpose
End the current Telnet session.
Syntax & Use
To end the current Telnet session, type:
BYE<Enter>
CLR ALM
Purpose
Clear all the alarms stored in the alarm buffer (including ON/OFF alarms).
Syntax & Use
To clear all the alarms, type:
CLR ALM/A<Enter>
CLR LOOP
Purpose
Deactivate the specified user-initiated test or loopback.
The FCD-E1LC rear-panel E1/T1 LOOPBACK switch can also be used to deactivate
the following loopbacks:
•
Main link local analog loopback
•
Main link remote analog loopback
•
Sublink local analog loopback
•
Sublink remote analog loopback.
The functions of this switch are described in Chapter 2. To deactivate a loopback,
the corresponding switch section must be returned to OFF (if necessary, first set
it to ON, and then back to OFF).
Syntax
CLR LOOP
Note