Specifications
Installation and Operation Manual Appendix A Connection Data
FCD-E1LC Ver. 1.0 Ethernet Port Connection Data A-19
TD
RTS
RD
3
2
7
9-Pin Male
Connector
FCD-E1LC Side
To CONTROL DCE
Connector
To Terminal
Terminal S ide
25-Pin Male
Connector
Figure A-10. 25-Pin Terminal Cable Wiring – Connection to CONTROL DCE
Connector
A.6 Ethernet Port Connection Data
The optional Ethernet port has a 10/100Base-T Ethernet interface terminated in
an RJ-45 connector, designated 10/100BASE-T. The port supports automatic
MDI/MDIX detection and crossover, and therefore can be connected by any type
of cable (standard or cross-over) to any type of 10/100Base-T Ethernet port
(station or hub). The connector pin functions corresponding to the standard hub
pinout are listed in
Table A-15
.
Table A-15. ETH Interface Connector, Pin Functions
Pin Designation Function
1
RxD+ Receive Data input, + wire
2
RxD– Receive Data input, – wire
3
TxD+ Transmit Data output, + wire
4, 5
– Not connected
6
TxD– Transmit Data output, – wire
7, 8
– Not connected