Specifications

Installation and Operation Manual Appendix A Connection Data
FCD-E1LC Ver. 1.0 Data Channel Connection Data A-15
FCD-E1LC Side Designation Function User’s Side
18 – Not connected
19 RTSB RTS (wire B) 31
20 RCEA External Receive Clock (wire A)
21 – Not connected
22 DSRB DSR (wire B) 24
23 RCEB External Receive Clock (wire B)
24 SCEA External Send Clock (wire A) 8
25 – Not connected
DTE2 Mode
This mode is used to connect to user’s equipment with V.36/RS-449 DCE
interface that provides the transmit and receive clocks to the FCD-E1LC data
channel.
The V.36/RS-449 cable coming from the user’s equipment is connected to the
FCD-E1LC CHANNEL connector through an adapter cable. The adapter cable (see
Figure A-8
) is terminated in a 25-pin male D-type connector at the FCD-E1LC
side, and a 37-pin female connector at the user’s side. A suitable cable,
designated CBL-HS2R3, is available from RAD.
Cable wiring is given in
Table A-12
.
Table A-12. Wiring of V.36/RS-449 Adapter Cable for DTE2 Mode
FCD-E1LC Side Designation Function User’s Side
1 FG Frame Ground 1
2 SDA Send Data (wire A) 6
3 RDA Receive Data (wire A) 4
4 RTSA RTS (wire A) 13
5 CTSA CTS (wire A)
6 DSRA DSR (wire A) 12
7 SG Signal Ground 19
8 DCDA DCD (wire A) 7
9 RCB Receive Clock (wire B)
10 DCDB DCD (wire B) 25
11 SCEB External Send Clock (wire B) 26
12 SCB Send Clock (wire B)
13 CTSB CTS (wire B)
14 SDB Send Data (wire B) 24