Specifications

Appendix A Connection Data Installation and Operation Manual
A-12 Data Channel Connection Data FCD-E1LC Ver. 1.0
Table A-9. Wiring of X.21 Adapter Cable for DCE Mode
FCD-E1LC Side Designation Function User’s Side
1 FG Frame Ground 1
2 SDA Send Data (wire A) 2
3 RDA Receive Data (wire A) 4
4 RTSA RTS (wire A) 3
5 CTSA CTS (wire A)
6 DSRA DSR (wire A)
7 SG Signal Ground 8
8 DCDA DCD (wire A) 5
9 RCB Receive Clock (wire B)
10 DCDB DCD (wire B) 12
11 SCEB External Send Clock (wire B)
12 SCB Send Clock (wire B) 13
13 CTSB CTS (wire B)
14 SDB Send Data (wire B) 9
15 SCA Send Clock (wire A) 6
16 RDB Receive Data (wire B) 11
17 RCA Receive Clock (wire A)
18 – Not connected
19 RTSB RTS (wire B) 10
20 RCEA External Receive Clock (wire A)
21 – Not connected
22 DSRB DSR (wire B)
23 RCEB External Receive Clock (wire B)
24 SCEA External Send Clock (wire A)
25 – Not connected
Connection Data for Data Channel with V.36/RS-449 Interface
The following sections provide information on the cables required to connect
user’s equipment to a data channel with V.36/RS-449 interface in the various
timing modes.