Specifications
Installation and Operation Manual Appendix A Connection Data
FCD-E1LC Ver. 1.0 Data Channel Connection Data A-11
FCD-E1LC Side Designation Function User’s Side
9 RCB Receive Clock (wire B) –
10 DCDB DCD (wire B) –
11 SCEB External Send Clock (wire B) X
12 SCB Send Clock (wire B) –
13 CTSB CTS (wire B) –
14 SDB Send Data (wire B) T
15 SCA Send Clock (wire A) –
16 RDB Receive Data (wire B) S
17 RCA Receive Clock (wire A) –
18 – Not connected –
19 RTSB RTS (wire B) –
20 RCEA External Receive Clock (wire A) Y
21 – Not connected –
22 DSRB DSR (wire B) –
23 RCEB External Receive Clock (wire B) AA
24 SCEA External Send Clock (wire A) V
25 – Not connected –
X.21 Data Channel
For the X.21 port, only a cable for use in the DCE mode designated CBL-HS2X1 is
available from RAD.
This mode is used to connect to user’s equipment with X.21 DTE interface. The
X.21 cable coming from the user’s equipment is connected to the FCD-E1LC
CHANNEL connector through an adapter cable. The adapter cable (see
Figure A-7
)
is terminated in a 25-pin male D-type connector at the FCD-E1LC side, and a
15-pin female connector at the user’s side.
Cable wiring is given in
Table A-9
.
Figure A-7. X.21 Adapter Cable for DCE Mode