Specifications

Installation and Operation Manual Appendix A Connection Data
FCD-E1LC Ver. 1.0 Data Channel Connection Data A-7
FCD-E1LC Side Designation Function User’s Side
23 RCEB External Receive Clock (wire B)
24 SCEA External Send Clock (wire A) 17
25 – Not connected
DTE2 Mode
This mode is used to connect to user’s equipment with DCE interface that
provides the transmit and receive clocks to the FCD-E1LC data channel.
In this case, it is necessary to connect a 25-pin male/25-pin male cross-cable (see
Figure A-5
) wired in accordance with
Table A-5
, between the FCD-E1LC CHANNEL
connector and the user’s equipment RS-530 connector.
Table A-5. Wiring of RS-530 Adapter Cable for DTE2 Mode
FCD-E1LC Side Designation Function User’s Side
1 FG Frame Ground 1
2 SDA Send Data (wire A) 3
3 RDA Receive Data (wire A) 2
4 RTSA RTS (wire A) 8
5 CTSA CTS (wire A)
6 DSRA DSR (wire A) 20
7 SG Signal Ground 7
8 DCDA DCD (wire A) 4
9 RCB Receive Clock (wire B)
10 DCDB DCD (wire B) 19
11 SCEB External Send Clock (wire B) 9
12 SCB Send Clock (wire B)
13 CTSB CTS (wire B)
14 SDB Send Data (wire B) 16
15 SCA Send Clock (wire A)
16 RDB Receive Data (wire B) 14
17 RCA Receive Clock (wire A)
18 – Not connected
19 RTSB RTS (wire B) 10
20 RCEA External Receive Clock (wire A) 15
21 – Not connected
22 DSRB DSR (wire B) 23