Specifications
Installation and Operation Manual Appendix A Connection Data
FCD-E1LC Ver. 1.0 Data Channel Connection Data A-5
Table A-3. Data Channel Connector, Pin Assignment
Pin Direction Designation Function RS-530 Circuit
1
↔
FG Frame Ground AA
2 Input SDA Send Data (wire A) BA(A)
3 Output RDA Receive Data (wire A) BB(A)
4 Input RTSA RTS (wire A) CA(A)
5 Output CTSA CTS (wire A) CB(A)
6 Output DSRA DSR (wire A) CC(A)
7
↔
SG Signal Ground AB
8 Output DCDA DCD (wire A) CF(A)
9 Output RCB Receive Clock (wire B) DD(B)
10 Output DCDB DCD (wire B) CF(B)
11 Input SCEB External Send Clock (wire B) DA(B)
12 Output SCB Send Clock (wire B) DB(B)
13 Output CTSB CTS (wire B) CB(B)
14 Input SDB Send Data (wire B) BA(B)
15 Output SCA Send Clock (wire A) DB(A)
16 Output RDB Receive Data (wire B) BB(B)
17 Output RCA Receive Clock (wire A) DD(A)
18 Input LLBA Local Loopback Activation (wire A) –
19 Input RTSB RTS (wire B) CA(B)
20 Input DTRA/RCEA DTRA/External Receive Clock (wire A) CD(A)
21 Input RLBA Remote Loopback Activation (wire A) –
22 Output DSRB DSR (wire B) CC(B)
23 Input DTRB/RCEB DTRB/External Receive Clock (wire B) CD(B)
24 Input SCEA External Send Clock (wire A) DA(A)
25 Output TMA Test Mode Indication (wire A) –
Connection Data for Data Channel with RS-530 Interface
The functions of the pins in the RS-530 data channel interface connector are
listed in
Table A-3
. The following sections provide information on the cables
required to connect user’s equipment to a data channel with RS-530 interface in
the various timing modes.
DCE Mode
This mode is used to connect to user’s equipment with DTE interface. The user’s
equipment can be directly connected to the FCD-E1LC channel connector using a
standard “straight” RS-530 cable (i.e., a cable wired point-to-point). The
“straight” cable is terminated in a 25-pin male D-type connector at the FCD-E1LC
side.