Specifications

Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics
FCD-E1LC Ver. 1.0 Testing the Unit 6-27
Table
6-11. Data Channel and Main Link Loopback Combinations
Additional Main Link
Loopback
Data Channel 1 and/or 2 Active
Loopback
Local Remote
Local Analog Yes No
Local Digital Yes No
Remote Analog Yes No
Remote Digital Yes No
BERT Yes No
TX Inband
Code Transmission
Yes No
RX Inband
Code Detection
Yes No
Table
6-12. Data Channel and Sublink Loopback Combinations
Additional Sublink
Loopback
Data Channel 1 and/or 2 Active
Loopback
Local Remote
Local Analog Yes Yes
Local Digital Yes Yes
Remote Analog Yes Yes
Remote Digital Yes Yes