6-16 Testing the Unit FCD-E1LC Ver. 1.0
6.5 Testing the Unit
The diagnostic loopbacks and tests are used to identify rapidly and efficiently the
location of a problem that prevents normal service.
A diagnostic loopback is activated by entering the appropriate LOOP (or LP)
command, and is deactivated using the CLR LOOP (or CLR LP) command. This
section provides a general description of each loopback and test.
Before executing a test, pay attention to the following:
• If a loopback is already connected, the TST indicator lights.
• If you try to connect a loopback while another loopback of the same type is
already connected, FCD-E1LC displays an error message.
• Not all of the loopback combinations are allowed.
For the list of allowed loopback combinations, refer to
Allowed Loopback
Combinations
on page
6-24
.
• No loopbacks are available for the Ethernet interface. In addition, main link
loopbacks should not be activated on an FCD-E1LC with Ethernet interface
while the Ethernet interface is connected to the LAN. This would cause a
state of permanent collision on the LAN, which would prevent other users
from using the LAN as long as the loopback is connected.
Overview of Test and Loopbacks
The FCD-E1LC supports the following types of test and loopback functions:
• Main link:
Main link local analog loopback (LP LOC ANA ML)
Main link remote analog loopback (LP REM ANA ML)
Main link local digital loopback (LP LOC DIG ML)
Main link remote digital loopback (LP REM DIG ML)
Inband-activated loopback (LP INBAND ML) on the main link
BER testing (LP BERT ML)
• Sublink:
Sublink local analog loopback (LP LOC ANA SL)
Sublink remote analog loopback (LP REM ANA SL)
Sublink local digital loopback (LP LOC DIG SL)
Sublink remote digital loopback (LP REM DIG SL)
• Data channel:
Data channel local loopback (LP LOC CH)
Data channel remote loopback (LP REM CH).