Error Code Terminal Message and Description
ERROR 004 CONFLICT IN INTERFACE AND DSR PARAMETERS
You selected DSR=ON after the supervisory port interface has been set to DTE. The
DSR=ON selection is valid only for DCE interface.
ERROR 005 TIMESLOT 16 OF E1-G732S FRAME IS MAPPED
You are trying to select the G732S framing mode while timeslot 16 is assigned to one of
the data channels or dedicated to inband management. Free timeslot 16 before
selecting the G732S framing.
ERROR 006 CONFLICT BEETWEEN FRAME AND TIME SLOT TYPES
The port uses G732N framing, but the specified timeslot is configured as a voice
timeslot. Change the type to data.
ERROR 007 CHANNEL SPEED NOT MATCH OPEN NUMBER OF TS
The number of timeslots currently allocated to the data channel is not equal to the
number of timeslots required to support the nominal data rate configured. Either
increase the number of timeslots, or reduce the channel data rate.
ERROR 008 FCD IN LOOP CAN’T UPDATE HARDWARE
When a test or loopback is active, it is not possible to change the FCD-E1LC operating
mode in accordance with the updated configuration parameters. You may see this
message either after pressing ENTER, or after a update data base command has been
received through the supervisory port (or inband management). You must first
deactivate the test or loopback.
ERROR 009 CONFLICT BETWEEN CLOCK MODE AND FIFO SIZE
You are trying to select the DCE or DTE1 clock mode when the FIFO size is not AUTO. A
specific FIFO size can be selected only for the DTE2 mode. Select AUTO.
ERROR 010 TIME-SLOT OUT OF RANGE
When using the SEQ or ALT mapping mode, the sum of the number of timeslots
requested for the data channel and the number of starting timeslot exceeds 31. Check
and change as required.
ERROR 011 ILLEGAL TIMESLOT ALLOCATION
The specified timeslot is allocated to more than one user. Check and correct timeslot
allocation.
ERROR 012 ILLEGAL UNFRAMED CONFIGURATION
You cannot configure the unframed mode when there are main link timeslots connected
to ports.
ERROR 013 ILLEGAL SPEED FOR AUXILIARY DEVICE
The AUTO (Autobaud) mode cannot be selected when the supervisory port is to support
the SLIP protocol (AUX DEV parameter is set to SLIP-NMS).
ERROR 014 WRONG IP ADDRESS
The syntax of the IP address is incorrect. The IP address must be entered in the
dotted-quad format (four numbers in the range of 0 through 255, separated by
periods), as explained in
Appendix B
.