User`s manual
RADview FCD-IP User’s Manual Chapter 5 Performance
Displaying E1/T1 Statistics 5-11
Table 5-5. DLCI Statistics Parameters
Parameter Possible Values / Remarks
Interface The selected interface.
DLCI The DLCI value.
FECN The number of frames received from the network indicating forward
congestion since the virtual circuit was created.
BECN The number of frames received from the network indicating backward
congestion since the virtual circuit was created.
Sent Frames The number of frames sent from this virtual circuit since it was created.
Sent Octets The number of octets sent from this virtual circuit since it was created.
Received Frames The number of frames received over this virtual circuit since it was created.
Received Octets The number of octets received over this virtual circuit since it was created.
Committed Burst The maximum amount of data, in bits, that the network agrees to transfer
under normal conditions, during the measurement interval.
Excess Burst The maximum amount of uncommitted data bits that the network will
attempt to deliver over the measurement interval.
Throught Put The average number of 'Frame Relay Information Field' bits transferred per
second across a user network interface in one direction, measured over the
measurement interval.
Circuit Discards The number of inbound frames dropped because of format errors, or
because the VC is inactive.
Received DE The number of frames received from the network indicating that they were
eligible for discard since the virtual circuit was created.
Sent DE The number of frames sent to the network indicating that they were eligible
for discard since the virtual circuit was created.