User`s manual
Chapter 3 Port Management RADview FCD-IP User’s Manual
3-38 Performing Diagnostic Tests
3.7 Performing Diagnostic Tests
RADview enables you to run diagnostic tests for: E1/T1 Link, E1/T1 Sublink,
SHDSL, SUB1/ LINK2, SUB 2, SUB 3, Voice Port.
When configuring TDM (Voice) parameters a password is required.
To run diagnostics tests:
1. Select a Link or Channel.
2. Select Diagnostics > Test…
The Testing dialog box appears.
Figure 3-28. Testing
Table 3-26. Testing Parameters
Parameter Possible Values / Remarks
Port The selected port.
Voice 1, Voice 2, Voice 3, Voice 4
Interface Type The interface type of selected port.
FXS, FX0, E&M 4 W, E&M 2W
Current Test The currently running test.
New Test
Remote Digital Loopback (T1 only), Remote Analog Loopback, Local Analog
Loopback
[Stop Test] Click <Stop Test> to stop a currently running test.
[Set] To run a different test, ensure that no test is currently running (click Stop Test). Select
the test to be run from the New Test list box and click <Set>.
To run a different test:
1. Click <Stop Test> to stop any currently running test.
2. Select a new diagnostic test.
3. Click <Set>.
Note