Chapter 3 Port Management RADview FCD-IP User’s Manual
3-16 Configuring Physical Parameters
Configuring E1/T1 Link Mode
• Link mode configuration is available for Main E1/T1 link for devices having two
E1/T1 ports.
• Note that, while the link mode can be configured only in the Edit View,
switching traffic between links can only be performed in Agent mode, which
detects the actual current mode of the link.
To configure E1/T1 link mode:
1. Select Link1.
2. Select Configuration >Physical Parameters > Mode….
The E1/T1 Link Mode dialog box appears.
Figure 3-11. E1/T1 Link Mode
Table 3-13. E1/T1 Link Mode
Parameter Possible Values / Remarks
Mode Normal,Chain,Ring SUB,Ring Main, Redundancy
Wait to Restore Wait to restore interval in minutes.
1-99
Note: This field is available only if Mode =Ring
Redundancy Online Primary, Secondary
Note: This field is available only if Mode = Redundancy
[Flip Cmd] Toggles the Redundancy Online parameter.
To change a redundant link from Primary to Secondary or vice versa, click <Flip
Cmd> and then confirm the command by clicking OK when the confirmation message
appears: “This operation will change the online link”
Note that this button is Password protected.