Specifications

Chapter 5 Configuring a Typical Application Installation and Operation Manual
5-8 Configuring Gmux-2000 MiTOP-E1/T1 Ver. 1.0
Pseudowire Gateway
Config>System>Management>Manager list
MNG NUM[1 - 100] ... (1)
1. IP ADDRESS ... (10.10.10.6)
2. NEXT HOP ... (0.0.0.0)
3. INTERFACE > (GIG A-IO 6/1)
4. TRAP(FOR MANAGER) (No)
5. VLAN VALID (No)
VLAN ID[0 - 4095] ... (0)
VLAN PRIORITY[0 - 7] ... (0)
Figure
5-11. Adding a Network Manager for Gmux-2000
Configuring the System Clock
Select the external clock, received via the STATION clock interface of the
CONTROL module, as a timing reference for the system.
³ To select the system clock:
From the Master Clock menu (Config > System > Clock source > System A >
Master clock), set the master clock source to Ext in-1.
Pseudowire Gateway
Config>System>Clock source>System A>Master clock
1. Master clock source > (Ext in-1)
2. Save parameters
Figure
5-12. Selecting the Gmux-2000 System Clock
Configuring the E1 Interface at the Physical Level
Before creating a bundle, configure the physical layer parameters of the external
E1 interface.
³ To configure the physical layer of the external E1 interface:
From the E1 Port menu (Config > Physical layer > E1 port), set:
Channel ID: 1
Transmit Clk Source: System A
Line Type: Framed G.704 CRC.