Specifications
Installation and Operation Manual Chapter 5 Configuring a Typical Application
MiTOP-E1/T1 Ver. 1.0 Configuring Gmux-2000 5-7
Pseudowire Gateway
Config>System>Card type
SLOT: PS-1 PS-2 PS-3 CL-1 CL-2
DB : PS-AC PS-AC PS-AC CL ---------
SLOT: IO/1 IO/2 IO/3 IO/4 IO/5
DB : CES E1 CES E1 --------- --------- ---------
SLOT: IO/6 IO/7 IO/8 IO/9
DB : GBeth --------- --------- ---------
1. ---------
2. PS-AC
3. PS-DC
Figure
5-9. Verifying the Hardware Configuration of Gmux-2000
Configuring Management Parameters
Configure the MiTOP-E1/T1 IP addresses to be used for the bundle connectivity
and management. Also add the NMS IP address to the manager list.
³ To configure the host IP address:
• From the Host IP menu (Config>System>Host IP), set the IP address of the
GbE module to 10.10.10.5.
Pseudowire Gateway
Config>System>Host IP
INTERFACE IP ADDRESS IP MASK DEFAULT GATEWAY
ONLINE CL: 0.0.0.0 0.0.0.0 0.0.0.0
GBETH 1/IF 1: 10.10.10.5 0.0.0.0 0.0.0.0
GBETH 1/IF 2: 0.0.0.0 0.0.0.0 0.0.0.0
Figure
5-10. Configuring the Host IP Parameters for Gmux-2000
³ To add a network manager:
1. From the Manager List menu (Config > System > Management > Manager list),
press A to add a manager to the manager list.
2. Set:
IP Address: 10.10.10.6.
Interface: GIG A-IO 6/1