Specifications
Chapter 5 Configuring a Typical Application Installation and Operation Manual
5-6 Configuring Gmux-2000 MiTOP-E1/T1 Ver. 1.0
³ To add a network manager:
1. From the Management menu (Configuration > System > Management), select
Manager List.
The Management List menu appears.
2. Use the arrow keys to move the cursor to the Manager IP field, select Change
Cell by typing 1 and enter the IP address of the management station.
3. Move the cursor to the Manager IP Mask field, select Change Cell by typing 1
and enter the subnet mask of the management station.
ETX-550
Configuration>System>Management>Manager List
Manager ID IP Address IP Mask Manager Trap Mask
1 10.10.10.4 255.255.255.0 Disable
2 0.0.0.0 255.255.255.0 Disable
3 0.0.0.0 255.255.255.0 Disable
4 0.0.0.0 255.255.255.0 Disable
5 0.0.0.0 255.255.255.0 Disable
6 0.0.0.0 255.255.255.0 Disable
7 0.0.0.0 255.255.255.0 Disable
8 0.0.0.0 255.255.255.0 Disable
9 0.0.0.0 255.255.255.0 Disable
10 0.0.0.0 255.255.255.0 Disable
x - Clear Table; d - Clear row
ESC-prev.menu; !-main menu; &-exit; ?-help
Figure
5-8. Adding a Network Manager for ETX-550
5.4 Configuring Gmux-2000
Gmux-2000 is a pseudowire gateway, which accepts the CESoPSN PW originating
from MiTOP-E1/T1, retrieves the TDM data and sends to the PBX. In addition,
Gmux-2000 receives a clock from an external source and supplies it as adaptive
timing to MiTOP-E1/T1.
Loading and Verifying the Hardware Configuration
When powering Gmux-2000 for the first time, the first step is to load the
hardware configuration, to cause Gmux-2000 to recognize the GbE and E1-PW/28
modules installed into the chassis.
³ To load and verify the hardware configuration:
1. From the Load Hardware menu (Config > Database tools > Load hardware),
load the necessary configuration, save and update the database.
2. From the Card Type menu (Config > System > Card Type) verify the correct
hardware configuration. Manually include any missing modules.