Specifications

Chapter 4 Configuration Installation and Operation Manual
4-10 Configuring MiTOP-E1/T1 for Operation MiTOP-E1/T1 Ver. 1.0
Defining the Adaptive Clock Quality
When the Rx clock source of a TDM interface is set Adaptive, it is necessary to
define the adaptive clock quality.
³ To define the adaptive clock quality:
From the Clock Recovery menu (Configuration > System > Clock Recovery),
select the quality of the adaptive clock source: Stratum 1, Stratum 2,
Stratum 3, Stratum 3E or Stratum 4.
Clock mode is permanently set to Auto.
MiTOP-E1/T1
Configuration > System > Clock Recovery
Source Quality Stratum 1
Clock Mode Auto
Figure
4-12. Clock Recovery Menu
Configuring Multiservice over PSN Application
MiTOP-E1/T1 units communicate with peer devices via pseudowire (PW)
connections that are established over the packet-switched network.
Use the following procedure to create PW connections over the packet-switched
network:
1. Define a MiTOP-E1/T1 peer device.
2. Create a pseudowire connection (PW), and configure its general, network and
service parameters.
Defining a Peer
A peer is a device which communicates with MiTOP-E1/T1 over a PW connection.
³ To define a peer:
From the Peer menu (Configuration > Applications
> Multiservice over PSN >
Peer), perform the following:
In the Peer Number field, enter the number of the peer to be added.
Currently MiTOP-E1/T1 supports a single peer device, with Peer Number
permanently set to 1.
In the Peer Name field, enter a description of the peer.
In the Peer IP Address field, enter an IP address of the peer device.
In the Next Hop field, enter the next hop address of the peer device.
In the Peer MAC Address field, enter a MAC address of the peer device.
Note