Specifications
Chapter 4 Configuration Installation and Operation Manual
4-2 Configuring MiTOP-E1/T1 for Management MiTOP-E1/T1 Ver. 1.0
MiTOP-E1/T1
Configuration > System > Management > Device Info
Description E1 Intelligent Converter
Device Name MiTOP-E1/T1
Location
Contact Person
Figure
4-1. Device Info Menu
Configuring the Host IP Parameters
In addition to defining the IP parameters of the MiTOP-E1/T1 host (see
Chapter 3
), the management software allows you to create a dedicated
management VLAN in order to separate management traffic from the user data.
³ To configure the host IP parameters:
• From the Host IP menu (Configuration > System > Management > Host IP), do
the following:
In the IP Address field, enter the host IP address
In the IP Mask field, enter the host IP mask.
In the Default Gateway field, set the default gateway IP address.
Set Host tagging to be Tagged or Untagged to consider or ignore the
VLAN tagging of the management traffic coming from the management
station.
If host tagging is enabled, enter:
Host VLAN ID (ID of the host VLAN): 1–4094
Host VLAN Priority (Priority of the host VLAN): 0–7
MiTOP-E1/T1
Configuration > System > Management > Host IP
IP Address 192.168.205.1
IP Mask 255.255.255.0
Default Gateway 0.0.0.0
Host Tagging Untagged
Figure
4-2. Host IP Menu