Specifications
Chapter 2 Installation and Setup Installation and Operation Manual
2-2 Connecting MiTOP-E1/T1 to the SFP-CA MiTOP-E1/T1 Ver. 1.0
³ To select the working mode:
• On MiTOP-E1/T1’s underside, set the DIP switches as listed in
Table
2-1
to
enable the desired working mode.
SW1SW2
OFF
ON
SW2 SW1 State
OFF OFF INIT DB
OFF ON Normal
ON OFF SW Dwnld
ON ON Config
Figure
2-1. DIP Switch Location
Table
2-1. DIP Switch Settings
Switch Position
Function
SW2 SW1
OFF OFF Database initialization
OFF ON Normal operation (factory setting)
ON OFF Software upgrade
ON ON Configuration
2.5 Connecting MiTOP-E1/T1 to the SFP-CA
For first use, you have to assign an IP address to MiTOP-E1/T1 and specify a
mode of operation. To do so, you can use RAD’s SFP-CA module illustrated in
Figure
2-2
. You can also use this module to upgrade the MiTOP-E1/T1’s software.
³ To connect MiTOP-E1/T1 to the SFP-CA unit:
1. Connect power to the SFP-CA unit.
2. Plug the USB connector of SFP-CA into a USB 2.0 port of a PC.
3. Plug MiTOP-E1/T1 into the SFP socket on the opposite side on the SFP-CA
unit.