Specifications
Installation and Operation Manual Appendix C I2C Interface Management
MiTOP-E1/T1 Ver. 1.0 SFP Identification Fields C-15
Field Name Data Address MiTOP-E1 MiTOP-T1
6 0 0
7 0 0
8 0 0
9 0 0
10 0 0
Encoding 11 0 0
BR_Nominal 12 0 0
Rate Identifier 13 0 0
Length (9u km) 14 0 0
Length (9u 100m) 15 0 0
Length (50u 10m) 16 30 30
Length (62.5u 10m) 17 0 0
Length (Copper 1m) 18 0 0
Length (OM3 10m) 19 0 0
Vendor Name 20–35 RAD Data Comm
(All unused ASCI
fields must be set
to 20h)
RAD Data Comm
(All unused ASCI
fields must be set to
20h)
Unallocated 36 0 0
Vendor OUI 37–39 0 0
Vendor PN 40–55 MiTOP-FE-E1 or
MiTOP-GE-E1
(All unused ASCI
fields must be set
to 20h)
MiTOP-FE-E1 or
MiTOP-GE-E1
(All unused ASCI
fields must be set to
20h)
Vendor rev 56–59 1.0 1.0
Wavelength 60–62 0 0
CC_BASE 63
Options 64 0 0
Options 65 12h 12h
BR, max 66 0 0
BR, min 67 0 0
Vendor SN 68–83 0 0
Date code 84–91 0 0
Diagnostic monitoring
type
92 0 0