Specifications

Installation and Operation Manual Appendix C I2C Interface Management
MiTOP-E1/T1 Ver. 1.0 General Parameters C-5
C.4 General Parameters
The following tasks can be performed:
Identify if MiTOP-E1/T1 is E1 or T1
Read the software version X.YZR, where each character in the version number
is one byte
Reset software
Reset to factory defaults.
Table
C-1. General Parameters
Index R/W Parameter
Length
Description Default
0x1 R 1 Module type
0x10: Mitop FE/E1
0x11: Mitop FE/T1
0x2 R 1 Software version X.YZR
0x00–0xFF
0x3 R 1 Software version X.YZR
0x00–0x63
0x4 R R Software version X.YZR. All
values are in ASCII code.
A: Alpha 0x41
B: Beta 0x42
D: Development 0x44
E: End of development 0x45
Null: Official release 0x00
0x5 R R Software version X.YZR
0x00–0x63
0x6 R 1 HW version X.YZR
0x00–0xFF
0x7 R 1 HW version X.YZR
0x00–0x63
0x8 R 1 HW version X.YZR. All values are
in ASCII code.
A: Alpha 0x41
B: Beta 0x42
D: Development 0x44
E: End of development 0x45
Null: Official release 0x00