- RAD Data Communications Ltd. RIC-E1 E1 Interface Converter Installation and Operation Manual

Package Contents 2-1
Chapter 2
Installation and Setup
This chapter explains how to configure and install RIC-E1.
After the installation is complete, refer to Chapter 3 for information about
operating RIC-E1.
Refer to Chapter 4 for troubleshooting and diagnostics information.
2.1 Site Requirements and Prerequisites
AC-powered RIC-E1 units should be installed within 1.5m (5 ft) of an
easily-accessible grounded AC outlet capable of furnishing the required supply
voltage, in the range of 100 to 240 VAC.
DC-powered RIC-E1 units require a -48 or 24 VDC power source, which must be
adequately isolated from the mains supply. In order to prevent a fire hazard, a
suitable fuse must be installed in the live DC line.
Allow at least 90 cm (36 in) of frontal clearance for operator access and at least
10 cm (4 in) clearance at the rear of the unit for interface cable connections.
The ambient operating temperature of RIC-E1 should be 0 to 50°C (32 to 122°F),
at a relative humidity of up to 90%, non-condensing.
2.2 Package Contents
The RIC-E1 package includes the following items:
RIC-E1 unit
The AC power cord or DC power supply connector kit
Ethernet over SDH/SONET and Converters CD
Jumper plug for JP9 jumper
CBL-530/449 adapter cable for units ordered with V.36 interface
RM-29 rack installation kit (if ordered).