Specifications

Chapter 3 Configuration Instructions Installation and Operation Manual
3-16 Setting Up Multiple NDRGs DXC-100PSX
Nest #1 Slot Configuration Menu
Slot# Device Type Name Redundancy
----- ---------------- ------ ------------
1 Octal T1/E1 NB Standby Enable
2 Octal T1/E1 Input 1 Enable
3 Octal T1/E1 Input 2 Enable
4 Octal T1/E1 Input 3 Enable
5 Octal T1/E1 Input 4 Enable
6 HDS-3 HDS3 1 Enable
7 HDS-3 BB2Standby Enable
8 STS-1 STS1 1 Disable
9 STS-1 STS1 2 Disable
10 HDS-3 HDS32 Enable
11 HDS-3 BB2Standby Enable
N+1 Redundancy: Enable
N+1 Redundancy Switchover: Automatic
N+1 Redundancy Restore: Manual
Change Card = [Enter key] [D]elete Card [P]ort/Link
Configuring
Figure
3-17. Slot Configuration Menu
18. Move your cursor to the
N+1 Redundancy Switchover
field, and press <Enter>
until the desired setting is obtained. The possible settings are as follows:
Narrowband Auto
- This setting enables a switchover to automatically
occur on just the narrowband devices in a Narrowband Redundancy
Group.
Broadband Auto
1 - This setting enables a switchover to automatically
occur on just the primary broadband devices located in slots 8-10 in a
Broadband 1 Redundancy Group.
Broadband Auto
2 - This setting enables a switchover to automatically
occur on just the primary broadband devices located in slots 1-6 in a
Broadband 2 Redundancy Group.
Automatic
- This setting enables a switchover to automatically occur on
an established Redundancy Group.
Manual
- A switchover will not occur until the operator does so manually.
The changes made to the N+1 Redundancy State are recorded dynamically. You
must exit the screen in order for your changes to take effect.
19. Once the desired setting is made, press X to exit and save.
There is no confirmation screen for this action.
Note
Note