Specifications

Installation and Operation Manual Chapter 3 Configuration Instructions
DXC-100PSX Setting Up Multiple NDRGs 3-15
Databases: NotInSync!!! N+1 Redundancy State: Frozen
Alarm Contacts..: Enabled Alarm Contact Type..: Standard
Nest #1 Slot Summary Menu
N+1
Slot# Group Configured Type Device State Alarm
----- ----- --------------- ------------ -----
01 Nb + Octal T1/E1 Online None
02 Nb - Octal T1/E1 Standby None
03 Nb + Octal T1/E1 Online None
04 Nb + Octal T1/E1 Online None
05 Nb + Octal T1/E1 Online None
06 Bb-2 + Hybrid DS-3 Online None
07 Bb-2 + Hybrid DS-3 Standby None
08 STS1 Online None
09 STS1 Online None
10 Bb-1 + Hybrid DS-3 Online None
11 Bb-1 + Hybrid DS-3 Standby None
SMCA System Manager A Standby None
SMCB System Manager B Online None
PSX ProtectionSwitch Online None
[C]lear error counts [T]oggle Alarm Contacts
N+1 Device Redundancy: Switch[O]ver [R]estore [E]xpose
Figure
3-16. N+1 Redundancy State Confirmed
N+1 Redundancy Switchover
The Protection Switch is capable of being configured to automatically back up
narrowband and broadband modules in the DXC-100. The N+1 Device
Redundancy (NDRG) Switchover can be configured to occur automatically for one
or both types of NDRGs. Although not advisable, the switchover can also be set
to
Manual
.
Configure N+1 Redundancy Switchover Options
1. From the DXC-100 Main Menu, select
System Configuration
, then
Slot
Configuration
. The Slot Configuration Menu appears: