Specifications
Chapter 3 Configuration Instructions Installation and Operation Manual
3-12 Setting Up Multiple NDRGs DXC-100PSX
available; configure your Broadband Group(s) as appropriate.
Octal E1/T1
(
D8E1T1)
will be the
N+1 Redundancy Narrowband Group
type.
12. Go back to the DXC-100 Main Menu and select
System Configuration
, then
select
Slot Configuration
. The following menu appears (6
Figure
3-13
):
13. Position the cursor next to the slot you want to configure and press <Enter>.
The following menu appears:
Slot Configuration
Nest............: 1
Slot............: 2
Slot Name.......: HDS3 #1
Card Type.......: HDS-3
Redundancy...: Enable
Figure
3-13. Card Slot Menu
14. Move your cursor to the
Slot name
field and press <Enter>, type in a slot
name, and press <Enter> again. In the above example,
HDS3 #1
is the named
slot.
15. Move your cursor to the
Card type
field and press <Enter> to scroll through
the card options until the desired card type appears. In the case of a
Broadband Group, select
HDS-3
(
DT3
or
DE3)
.
16. Move your cursor to the
Redundancy
field and press <Enter> until
Enable
is
displayed.
To “enable” redundancy for the Broadband Redundancy Group you must have
selected DT3 or DE3 as the card type.
17. To exit and save changes, press X. When prompted: “Update Configuration?
Are you sure? (Y/N)” press Y. You are returned to the Slot Configuration
Menu.
Note