Specifications

Installation and Operation Manual Chapter 3 Configuration Instructions
DXC-100PSX Setting Up Multiple NDRGs 3-9
To enable redundancy for the Narrowband Redundancy Group you must have
selected Octal T1/E1
as the card type.
9. To exit and save changes, press X. When prompted: “Update Configuration?
Are you sure? (Y/N)” press Y. You are returned to the Slot Configuration
Menu.
Narrowband Redundant Device
View Information on the Narrowband Redundant Device in
Slot 1
1. From the DXC-100 Main Menu, select
Nest Summary.
The following menu
appears:
Standby SMC not present N+1 Redundancy State: Enabled
Alarm Contacts..: Enabled Alarm Contact Type..: Standard
Nest #1 Slot Summary Menu
N+1
Slot# Group Configured Type Device State Alarm
----- ----- --------------- ------------ -----
01 Nb + Octal T1/E1 Online *None Clock Src
02 Nb - Octal T1/E1 Standby *Major
03 Nb + Octal T1/E1 Online None
04 Nb + Octal T1/E1 Online None
05 Nb + Octal T1/E1 Online None
06 Bb-2 + Hybrid DS-3 Online None
07 Bb-2 + Hybrid DS-3 Standby None
08 STS-1 Online None
09 STS-1 Online None
10 Bb-1 + Hybrid DS-3 Online None
11 Bb-1 + Hybrid DS-3 Standby None
SMCA System Manager A Standby None
SMCB System Manager B Online None
PSX ProtectionSwitch Online None
[C]lear error counts [T]oggle Alarm Contacts
N+1 Device Redundancy: Switch[O]ver [R]estore [E]xpose
Figure
3-10. Nest Summary Menu
Note