Specifications

DXC-100PSX Verifying Protection Switch Installation 3-1
Chapter 3
Configuration Instructions
3.1 Verifying Protection Switch Installation
To ensure that the Protection Switch has been properly installed, verify the Card
Status is
Ok
and the Switch State’s condition is
Normal.
For detailed craft terminal operating instructions refer to the DXC-100 Installation
and Operation Manual.
³ To verify the protection switch installation:
1. From the DXC-100 Main Menu, move your cursor to the
Nest Summary
field
and press <Enter> The Nest Summary Menu appears:
Standby SMC not present N+1 Redundancy State: Enabled
Alarm Contacts..: Enabled Alarm Contact Type..: Standard
Nest #1 Slot Summary Menu
N+1
Slot# Group Configured Type Device State Alarm
----- ----- --------------- ------------ -----
01 Octal T1/E1 Standby None Clock Src
02 Octal T1/E1 Online None
03 Octal T1/E1 Online None
04 Octal T1/E1 Online None
05 Octal T1/E1 Online None
06 Hybrid DS-3 Online None
07 Hybrid DS-3 Standby None
08 STS-1 Online None
09 STS-1 Online None
10 Hybrid DS-3 Online None
11 Hybrid DS-3 Standby None
SMCA System Manager A Standby None
SMCB System Manager B Online None
PSX ProtectionSwitch Online None
[C]lear error counts [T]oggle Alarm Contacts
N+1 Device Redundancy: Switch[O]ver [R]estore [E]xpose
Figure
3-1. Nest Summary Menu
2. Verify that the Protection Switch is
Online
by looking in the device state
column. Move your cursor to the
DXC-100PSX
field and press <Enter>. The
Note