Specifications
Chapter 2 Module Installation and Operation Installation and Operation Manual
2-2 Installing and Connecting the Protection Switch DXC-100PSX
3. Connect the opposite end to the DB9 connector located on the DSMC.2 rear
interface module, marked PROTECT SWT.
4. Install the primary and redundant interface modules.
The DXC-100PSX Primary and Redundant Interface Module components are
sensitive to electrostatic discharge. When handling these modules, wear an
anti-static wrist strap connected to frame ground to prevent damage to circuits
from electrostatic discharge.
The Primary and Redundant Interface modules have a one-to-one
correspondence with the DXC-100 Interface modules; see
0
Table
2-1.
Table
2-1. One-to-One Correspondence
Slot Module
Slot 1 Narrowband Redundant Card, D8E1T1/R
Slots 2 to 11 Narrowband Primary Card, D8E1T1/P
Slot 11 Broadband Redundant Card, DE3T3/R
Slots 8 to 10 Broadband Primary Card, DE3T3/P
Slot 7 Broadband Redundant Card, DE3T3/R
Slots 1 to 6 Broadband Primary Card, DE3T3/P
Narrowband Redundancy Connections
1. Connect the 50-pin cable from the network to the 50-pin connector on the
DXC-100PSX Narrowband Primary module.
5. Connect the 50-pin cable from the Narrowband Primary module to the
corresponding 50-pin connector on the DXC-100 Narrowband (D8E1T1) rear
interface module.
6. Attach the 50-pin male-to-male cable (CBL-100PSX-D8E1T1) from the
Narrowband Redundant module to the Standby slot 1 on the DXC-100.
1
Figure
2-2
illustrates a DXC-100PSX connection for Narrowband Redundancy.