Specifications

Installation and Operation Manual Chapter 1 Overview
DXC-100PSX Technical Specifications 1-19
Table
1-6. Narrowband Switchover Times
Error Type Switchover Time
Missing System Clock ~5 seconds
Missing Frame Sync Pulse ~5 seconds
Invalid Backplane Timeslot Management ~5 seconds
Incorrect Framer Values ~1 second
Lost communications with System Manager ~60 seconds
Missing Application Module (Front Card) ~1 second
Missing Interface Module (Rear Card) ~5 seconds
Missing DXC-100/DXC-100PSX Cable ~1 second
Commanded Switchover <50 milliseconds
1.4 Technical Specifications
General
Configuration
Can be configured with a standalone DXC-100
chassis
Can be configured in a DXC-100 stack node
Certifications
FCC Part 15 and Part 68, IC, UL1950, IC CSO3,
IC-003, EN60950, EN55022, EN50082, NEB/L3,
CTR 12/13, CB Scheme
Power Supply
-48VDC ±10%, max. 48W
Slots
11 primary/redundant module slots, plus 2 power
supply slots and 1 controller slot
Dimensions
133 mm (5.25”) H (3 RU) x 432 mm (17”) W x
356 mm (14”)
Weight
12.5 kg (27.5 lbs) fully loaded
Mounting
Rack mount (19" or 23") Flush or Center Mount
Input Power
-48 VDC ±10%, Max. 48 Watts
Fuse
F1 (in DC Power Supply Module): 2 Amp, 125V,
Fast Acting
Environment
Temperature: 0° (32°F) to 50°C (122°F)
Humidity: 0% to 90% (non-condensing)