Specifications

Installation and Operation Manual Chapter 1 Overview
DXC-100PSX Functional Description 1-13
Fan Assembly
The field-replaceable exhaust fan assembly removes the heated air from the
DXC-100PSX enclosure as well as the associated DXC-100 nest.
1
Figure
1-10
shows the front-mounted fan assembly (containing three fan units) with the
front cover removed.
Figure
1-10. Fan Assembly (without Front Cover)
1.3 Functional Description
Broadband Redundancy
Broadband Normal Operation
During normal (non-fault) conditions, broadband user traffic to and from the
network passes through the latching relays within the DXC-100PSX primary
interface module which is directly attached to the link. If it is not already
protecting another DXC-100 broadband module set within one of the two user
defined broadband protection groups (BB1 supporting up to 3+1 or BB2
supporting up to 6+1 module redundancy), the redundant broadband module set
will be performing self-test diagnostics via the looped back path within the
DXC-100PSX redundant interface module.
In the event that a fault or failure is detected within the standby module set, that
given broadband redundancy group will be disabled for the duration of the fault