Specifications

Chapter 1 Overview Installation and Operation Manual
1-12 Physical Description DXC-100PSX
Broadband Redundant Module, DE3T3/R
The Broadband Redundant Module is designed to interface with the DXC-100-
resident standby DT3 or DE3 interface module via a set of BNC interconnection
cables. This module is used to facilitate DXC-100-commanded interface switching
to the standby module from the protected module (via latching relays). The
Broadband Redundant Module must be installed in DXC-100PSX slot 7 for
Broadband Group 2, or in DXC-100PSX slot 11 for Broadband Group 1. The
standby DT3 or DE3 module set must be installed in a matching slot (slot 7 or 11)
in the DXC-100 chassis.
Thumbscrews are provided at the top and bottom of the faceplate to secure the
module in the chassis and to make an electrical connection to frame ground for
regulatory emission compliance. See
1
Figure
1-8
for an illustration of a Broadband
Redundant Module.
Figure
1-8. Broadband Redundant Module
D/E3T3/R
OUT TX
RX
One set of individual BNC (AMP 415085-1 locking bayonet-type) female
receptacles (two total) are mounted on the Broadband Redundant interface
module with the OUT pair interfacing the associated DXC-100 resident module
set.
See
1
Figure
1-9
for the OUT connector configuration and labeling.
Broadband Redundant OUT Connectors
TX
Transmit (to DXC-100)
Shield Groun
d
RX
Receive (from DXC-100)
Shield Ground
Figure
1-9. Broadband Redundant Module BNC Connector Configuration and
Pinouts