Specifications
Chapter 4 Troubleshooting and Diagnostics D8E1T1 Installation and Operation Manual
4-20 Expose (Link Status)
15-min Performance Registers For Port#: 2
INT ES FS SES BES INT ES FS SES BES INT ES FS SES BES
-----------------------------------------------------------------
01. 000 900 000 000 17. 000 000 000 000 33. 000 000 000 000
02. 000 900 000 000 18. 000 000 000 000 34. 000 000 000 000
03. 000 900 000 000 19. 000 000 000 000 35. 000 000 000 000
04. 000 900 000 000 20. 000 000 000 000 36. 000 000 000 000
05. 001 891 001 000 21. 000 000 000 000 37. 000 000 000 000
06. 000 000 000 000 22. 000 000 000 000 38. 000 000 000 000
07. 000 000 000 000 23. 000 000 000 000 39. 000 000 000 000
08. 000 000 000 000 24. 000 000 000 000 40. 000 000 000 000
09. 000 000 000 000 25. 000 000 000 000 41. 000 000 000 000
10. 000 000 000 000 26. 000 000 000 000 42. 000 000 000 000
11. 000 000 000 000 27. 000 000 000 000 43. 000 000 000 000
12. 000 000 000 000 28. 000 000 000 000 44. 000 000 000 000
13. 000 000 000 000 29. 000 000 000 000 45. 000 000 000 000
14. 000 000 000 000 30. 000 000 000 000 46. 000 000 000 000
15. 000 000 000 000 31. 000 000 000 000 47. 000 000 000 000
16. 000 000 000 000 32. 000 000 000 000 48. 000 000 000 000
[N]ext Page
Figure 4-13. 15-Minute Performance Registers Display
Press N to view the next 48 intervals. The information contained in each field on
the screen is detailed in Table 4-10.
Table 4-10. 15-Minute Performance Registers Display Field Descriptions
Field Description
INT (Interval):
(display field)
The interval number for the ninety-six 15-minute intervals preceding the
current interval, with 01 being the most recent.
ES (Errored Seconds):
(display field)
The occurrence of a Loss of Frame or a CRC6 error in a one-second period is
known as an errored second. This field displays the number of errored seconds
that have occurred.
FS (Failed Seconds):
(display field)
Each one-second period during the occurrence of a Failed Signal State (ten
consecutive errored seconds) is known as a failed second. This field displays the
number of severely errored seconds that have occurred.
SES (Severely Errored
Seconds): (display field)
A one-second period in which three hundred twenty (320) or more CRC6
errors have occurred is known as a severely errored second. This field displays
the number of severely errored seconds that have occurred.
BES (Bursty Errored
Seconds): (display field)
(displayed for T1 links only)
A one-second period in which more than one but less than 320 CRC6 errors
has occurred is known as a bursty errored second. This field displays the
number of bursty errored seconds that have occurred.