Specifications
Chapter 4 Troubleshooting and Diagnostics D8E1T1 Installation and Operation Manual
4-8 Diagnostic Loops
Link: 1
Loop Select Screen
-------------------
NI Loop Type..: Off
Backplane Loop: Off
NI Loop Type : [O]ff [L]ocal Li[n]e [A]nalog [R]emote [P]ayload
[S]martJack [U]ser Defined
Backplane Loop: [T]oggle
Figure 4-5. Loop Selection Screen
1. To select a specific loop, either place the cursor on the NI Loop Type field and
press <Enter> to cycle through the choices OR press the specific key
indicated on the bottom of the menu. The selectable Link loops are described
in Table 4-6, and illustrated in Figure 4-7.
2. Once you have selected a loop, press X to enable it. The following prompt
appears:
Link: 1
************************************
* *
* -MESSAGE!- *
* *
* *
* Process Loop Command ? *
* *
* *
* Are you sure (Y/N)? *
* *
************************************
NI Loop Type : [O]ff [L]ocal Li[n]e [A]nalog [R]emote [P]ayload
[S]martJack [U]ser Defined
Backplane Loop: [T]oggle
Figure 4-6. Process Loop Prompt
3. Press Y to initiate the loop, and you are returned to the Diagnostics Manager
Menu. Press N to exit and return to the Diagnostics Manager Menu.