Specifications

Chapter 4 Troubleshooting and Diagnostics D8E1T1 Installation and Operation Manual
4-2 Diagnostics Center (Diagnostics Manager Menu)
Table 4-1. D8E1T1 Diagnostics Menu Option Table
Option Description
Line Diagnostics Center
Opens the Diagnostics Center (Diagnostics Manager Menu) Menu, where the
status of the T1/E links are displayed, and from which several submenus may
accessed to perform additional diagnostic actions such as loopbacks, BERT, error
insertion, and viewing additional statistics.
Monitor Control Signals
Selecting Monitor Control Signals opens the PCM Signalling Display Menu, which
allows you to monitor the payload signaling states and transceiver control signals
on a per-link basis.
4.2 Diagnostics Center (Diagnostics Manager Menu)
The Line Diagnostics Center (Diagnostics Manager Menu) is used to set up line
diagnostics for the D8E1T1 module.
Navigation:
D8E1T1 Main Menu
Diagnostics
Line Diagnostics Center
Diagnostics Manager
- - - - - - - - - - - -
Errored Link Bkpln Test Bert
Link Name State Seconds Loop Loop Bert Duration Errors
------------ -------- ------- ------- ----- ------- --------- ------
Circuit Num *ERROR* 3062 Off Off Off 0 0
Circuit Num *ERROR* 3062 Off Off Off 0 0
Circuit Num Inactive 0 Off Off Off 0 0
Circuit Num Inactive 0 Off Off Off 0 0
Circuit Num Inactive 0 Off Off Off 0 0
Circuit Num Inactive 0 Off Off Off 0 0
Circuit Num Inactive 0 Off Off Off 0 0
Circuit Num Inactive 0 Off Off Off 0 0
[B]ert [L]oop [E]xpose [C]lear Error Counters
ESF [S]tatistics 15-min Performance [R]egisters [G].826
------------ Hit key 1 thru 9 to insert an error ------------
[1]CAS Multiframe [2]Multiframe [3]PRBS [4]FBit
[5]Frame Alignment [6]Line Code Violation [7]Bit Slip [8]CRC [9] All
Figure 4-2. Diagnostics Manager Menu