Specifications

Chapter 3 Configuration D8E1T1 Installation and Operation Manual
3-14 N+1 Redundancy Menu
N+1 Redundancy Status Menu
Navigation:
D8E1T1 Main Menu
N+1 Redundancy
Device Redundancy
N+1 Redundancy Status Menu
Member of Redundancy Group: No
Card Type.................: Primary
Device State..............: Online
State Change Count
---------------------
Frame Sync Pulse.............: OK 0
System Clock.................: OK 0
Backplane Timeslot Management: OK 0
Communication with System Mgr: OK 0
Rear Card....................: OK 0
Framers......................: OK 0
[C]lear counters
Figure 3-15. N+1 Redundancy Status Menu
The N+1 Redundancy Status Display is a read-only screen. The only action that
can be accomplished here is pressing C to clear the counters. Descriptions for each
field on this screen are supplied in Table 3-2.