Specifications
D8E1T1 Installation and Operation Manual Chapter 3 Configuration
N+1 Redundancy Menu 3-13
Link Configuration
--------------------
Link Nbr......: 8
Name..........: Circuit Number
Status........: In Service
Clear T1/E1...: Disabled
LineType......: E1-CAS-CRC
Network Loop..: Disabled
Tx Yel Alm/RAI: Yes
Unused DSO's..: Busy
Long Haul.....: S-Haul
Figure 3-13. View Individual T1/E1 Link Configuration Menu (E1 Example)
From here, you can view the configuration of one link at a time. Refer back to
Table 3-1 for an explanation of the fields in this menu.
3.6 N+1 Redundancy Menu
The N+1 Redundancy Menu allows you to view N+1 Redundancy Status. It is
applicable to DXC-100 units equipped with the DXC-100 PSX Protection Switch.
For specific information and instructions on setting up a D8E1T1 module set in a
redundancy group, refer to the DXC-100 Installation and Operation Manual.
If you have only one D8E1T1 module set installed in your DXC-100, Redundancy
must be set to “Disabled”.
Navigation:
D8E1T1 Main Menu
↓
N+1 Redundancy
N+1 Redundancy Menu
---------------------
Device Redundancy
Figure 3-14. D8E1T1 Module N+1 Redundancy Menu
Note