Specifications
D8E1T1 Installation and Operation Manual Chapter 3 Configuration
D8E1T1 Module Configuration 3-5
Nest #1 Slot #10 Links Configuration
Network Yel Idle
Link Name Framing FDL LH/LBO Loop Alarm Code
-- -------------------- ----------------- ------ ------- ------- ----- ----
01 Circuit Number T1 ESF B8ZS 54016 0.0db Disable Yes Busy
02 Circuit Number T1 ESF AMI 62411 54016 0.0db Disable Yes Busy
03 Circuit Number T1 ESF AMI CLEAR 54016 0.0db Disable Yes Busy
04 Circuit Number T1 D4 B8ZS 0.0db Disable Yes Busy
05 Circuit Number E1 S-Haul Disable Yes Busy
06 Circuit Number E1-CRC S-Haul Disable Yes Busy
07 Circuit Number E1-CAS S-Haul Disable Yes Busy
08 Circuit Number E1-CAS-CRC S-Haul Disable Yes Busy
LH - long haul LBO - line build out[T1 only] FDL - facility data link
[C]opy cfg to all
Figure 3-5. D8E1T1 Link Configuration Menu
1. To change parameters for an individual link, move the cursor to the link to be
changed and press <Enter>. The following menu appears:
Nest #1 Slot #10 Link Configuration
Link Nbr......: 1
Name..........: Circuit Number
Status........: In Service
Clear T1/E1...: Disabled
LineType......: T1 ESF B8ZS
Network Loop..: Disabled
Tx Yel Alm/RAI: No
Unused DSO's..: Busy
ESF format....: 54016
LBO...........: 0.0db <> Long Haul
Recover Time..: 3 seconds
Figure 3-6. Individual Link Configuration Menu (T1 Example)