D8E1T1 Installation and Operation Manual Chapter 3 Configuration
Configure a Slot for a D8E1T1 Module 3-3
Slot Configuration
Nest: 1
Slot: 10
Slot Name:
Card Type:
Redundancy: Disable
Figure 3-3. Slot Configuration Submenu
4. Place your cursor on the Slot Name field and press <Enter>. Type in a slot
name or number of up to 11 alphanumeric characters and press <Enter>
again.
5. Select a card type. Move your cursor to the Card type field and press
<Enter>. The Card Type Menu appears:
Select a Card Type
1) XCC 2) XLC 3) XLCOT1E1
4) STM1 5) STM1X 6) OC3
7) OC3X 8) STS1 9) HDS3
10) DS3 11) E3 12) OT1E1
13) QT1 14) OHSD 15) QHSD
16) DS0-DP 17) OCU-DP 18) TAM
19) ROUTER 20) OCTAL VOICE
Enter Card Type Number: 0
Figure 3-4. Select a Card Type Menu
6. Press <Enter>, type in the number of the D8E1T1 module (12), then press
<Enter> again to store the device type.
7. Press X to save module type and return to the Slot Configuration Submenu.
8. For DXC-100 units with the N+1 Protection Switch, move your cursor to the
Redundancy field to Enable or Disable redundancy as desired.
The Redundancy field will only be displayed if Narrowband Redundancy has been
Enabled and set to D8E1T1 via the Nest Profile Menu. In order to utilize N+1
redundancy, a D8E1T1 module must be installed in one of the slots 2 to 10, with a
redundant module installed in slot 1 (for Narrowband Group 1).
9. Press X to save changes. When prompted: “Update Configuration? Are
you sure (Y/N)?”
Press Y. You are returned to the Slot Configuration menu.
Note