Specifications
Chapter 2 Installation and Operation D8E1T1 Installation and Operation Manual
2-4 Normal Indications
• Use the cable tie mount below the connector to attach a tie-wrap around a
standard interface cable, such as CBL-DXC100-D8E1T1/BAL, that feeds from
below the DXC-100.
Refer to Figure 2-1 for a detailed view of tie-wrap attachment locations.
P1
Tie Wrap (Mounting location
shown for DXC-100 with N+1
Protection Switch)
Tie Wrap attachment
mount for DXC-100 without
N+1 Protection Switch
Figure 2-1. Tie-Wrap Attachment Locations
2.4 Normal Indications
D8E1T1 Status Indication
When a D8E1T1 module is operational, its READY indicator lights in green.
For a module in the standby state (N+1 redundancy implemented), the READY
indicator flashes in green.
Link Status Indications
The status of each D8E1T1 link is indicated by a separate set of indicators. The
normal indications for an operational link interface are as follows:
• The STATUS indicator of an active link lights in green.
• The TEST indicator is off. It lights in yellow when a BER test or loop is activated
on the corresponding link.