Specifications
Chapter 2 Installation and Operation D8E1T1 Installation and Operation Manual
2-2 Connecting the Cables
2.2 Installing D8E1T1
To use N+1 redundancy, D8E1T1 must be installed in slots 2 to 10, with a
redundant module installed in slot 1 (for Narrowband Group 1).
Application Module Installation
1. Hold the application module vertically with the components on the left.
2. Slide the application module into a slot in the front of the DXC-100 chassis
following the white card guides.
3. Open both card ejectors until they are at a 90-degree angle to the module,
then slide the module further into the slot until the hook on the card ejectors is
inside the lip of the DXC-100 chassis.
4. Slowly close the card ejectors, which seats the application module in the slot.
5. Tighten the thumbscrews at the top and bottom of the application module.
Interface Module Installation
1. Hold the interface module vertically with the components on the right.
2. Slide the interface module into a slot in the rear of the DXC-100 chassis
following the white card guides.
3. Seat the interface module by slowly pressing it into place.
4. Tighten the thumbscrews at the top and bottom of the interface module.
2.3 Connecting the Cables
Link Connection Data
The D8E1T1 interface module has a 50-pin RJ48M connector designated P1.
Table 2-1 lists the connection pin functions.
Straight cable CBL-DXC100-D8E1T1/BAL, or cross-cable
CBL-DXC100-D8E1T1/BAL/X, terminated in 8 RJ-45 connectors, can be ordered
from RAD.
Note