Specifications

Chapter 5 Configuring a Typical Application ASMi-52 Installation and Operation Manual
5-4 Configuring the ASMi-52 units
ASMi-52
SHDSL local port configuration
1. Power backoff (Enable)
2. Snext margin (Disable)
3. Current margin (Disable)
4. Asym PSD (Symmetrical)
5. Line prob (Adaptive rate)
6. Configured wire (4W)
7. Loop attenuation threshold (dB) [0-127] (0)
8. SNR margin threshold (dB) [0-15] (0)
9. Save
>
ESC-prev.menu; !-main menu; &-exit; @-scroll
2. Select Configured wire
The display is refreshed and a new value appears (4W).
3. Select Save to save the change
4. Reset ASMi-52 in order to activate the change.
Setting the E1 port
To select E1 framing mode:
1. Display the Framed Mode screen (Main menu > Configuration > Physical
Ports Configuration > E1 Port Configuration menu > Framed Mode)
The Framed Mode menu appears.
ASMi-52
Framed mode (Unframed)
1. Unframed
2. G732N
3. G732S transparent
>
ESC-prev.menu; !-main menu; &-exit; @-scroll
2. From the Framed Mode menu, select Unframed to choose unframed
operation.
The E1 Port Configuration menu appears.
3. Save the changes.
After performing these configuration procedures, the ASMi-52 units are ready to
be connected.