Specifications

ASMi-52 Installation and Operation Manual Chapter 1 Introduction
Technical Specifications 1-9
Control Port
Type
DTE/DCE
Format
8 bits, no parity
Baud Rate
9.6, 19.2, 38.4, 57.6, 115.2 kbps
Connector
9-pin, D-type female
Interface
10/100BaseT
Ethernet
Control Port
Protocol
MAC
Connector
RJ-45
Timing
Derived from three alternative sources:
Internal oscillator
External, from the attached DTE
Receive, derived from the received signal
Diagnostics
Loopbacks
ITU V.54:
Local loopback, activated via management software or by
the DTE interface signal (V.35 and RS-530 only)
Remote loopback, activated via management software or
by the DTE interface signal (V.35 and RS-530 only)
Remote loopback at SHDSL repeater
Statistics Collection
E1 with CRC-4 or T1 with ESF framing: per ITU G.706
E1 without CRC-4 or T1 with SF framing: bipolar
violations (BPV)
SHDSL performance
Alarm Relay
Operation
Normally Open and Normally Closed, using different pins
Connector
Terminal block, 6-pin
Indicators
PWR (green)
Power
TEST (red)
Test
SYNC A/B
(green/red)
Synchronization of DSL line
DATA (yellow)
Data Transfer (except E1 and T1 options)
E1/T1 SYNC (red)
Loss of E1/T1 synchronization (E1 and T1 options only)
AIS (yellow)
“All 1s string” is received at the E1 interface
(E1 option only)
YELLOW (yellow)
“All 1s string” is received at the T1 interface
(T1 option only)
ALM (red)
Alarm