Specifications

Installation and Operation Manual Chapter 4 Configuration
ASMi-52 Ver. 2.8 Configuring for Operation 4-23
Unframed – Stream of bits at 2.048 Mbps
G732N – Timeslot 0 contains sync word
G732S transparent – 16 frames per multi-frame, timeslot 16 is passed
transparently.
If the opposite modem is E1, then the Framed Mode value can be is G732N,
G732S Transparent, or Unframed.
If the opposite modem is Serial DTE or LAN, then the Framed Mode value can
be G732N, or Unframed
If Frame Mode is Unframed, then all the rest of the parameters are disabled.
Sync mode: define the time required for the E1 port to return to normal
operation after sync loss:
CCITT – As per requirements of ITU-T Rec.G.732
Fast – After 1 sec
62411 – As per requirements of AT&T TR-62411 (after 10 sec).
CRC-4: Enabling generation and checking of check bits for the frames
transmitted on the E1 port (as per CRC-4 polynomial specified by ITU G.704).
Check bits generation is available only for the G732N framing mode.
Idle Code: Selecting a code transmitted to fill unused timeslots in the E1
frames.
Time Slot Assignment – Assigning each timeslot to carry user’s data
Unit Identical Set
Yes – copies Sync Mode, Time Slot Assignment and Idle Code definitions
to the remote modem
No – Sync Mode, Time Slot Assignment and Idle Code must be defined in
both modems individually
First time slot for remote E1 – define the first time slot for the remote E1
unit.
The E1 port configuration is performed via the E1 Configuration menu.
³ To access the E1 Port Configuration menu:
From the E1 Configuration menu, select E1 Local Port/E1 Remote Port (Main
menu > Configuration > E1 Configuration > E1 Local Port/E1 Remote Port).
The E1 Local Port/E1 Remote Port menu appears (see
Figure
4-26
and
Figure
4-27
).
Note