Specifications

Chapter 4 Configuration Installation and Operation Manual
4-12 Configuring ASMi-52 for Management ASMi-52 Ver. 2.8
not established on the first attempt, ASMi-52 makes the specified
number of redials.
This parameter applies to both primary and alternate numbers:
If the call is not established after dialing the primary directory number
the specified number of times, ASMi-52 attempts to establish the call
by dialing the alternate directory number (provided the use of an
alternate number is enabled).
If the call is not established within the specified number of redialing
attempts on neither of the two directory numbers, ASMi-52 stops the
call attempts. When a new alarm report must be sent, the call
attempts are started again. The user is notified that the call attempts
failed by a message recorded in the alarm log file (separate messages
are provided for each directory number).
3 to specify the time (in sec) ASMi-52 waits for an answer after each
dialing attempt. If the called station does not answer within the specified
time, ASMi-52 disconnects. If additional call attempts are allowed,
ASMi-52 redials immediately after disconnecting. The available selections
are 30, 45, or 60 seconds.
4 to select the dialing mode. TONE, if the dial-out modem is instructed to
use DTMF dialing. PULSE, if the dial-out modem is instructed to use pulse
dialing.
5 to control the use of an alternate number. The alternate number is
dialed after the specified number of call attempts on the primary number
failed.
ENABLE, the use of an alternate number is enabled. DISABLE, ASMi-52
stops the call attempts after the specified number of call attempts on the
primary number failed.
6 to specify a primary number to dial.
7 to specify an alternate number to dial.
3. Select Save to save the changes.
ASMi-52
Dial out
Call Out Mode (None)
Number of Retries [0-8] (1)
Wait for connect (sec) (30 sec)
Dial mode (Tone)
Alternate number mode (Disable)
Primary number ()
Alternate number ()
Save
>
ESC-prev. menu; !-main menu; &-exit; @-scroll
Figure
4-16. Control Port Dial Out Menu