Specifications
ASMi-52 Ver. 2.8 Configuring ASMi-52 for Management 4-1
Chapter 4
Configuration
4.1 Configuring ASMi-52 for Management
The configuration of ASMi-52 is performed via a menu-driven embedded
software, using a standard ASCII terminal or a PC running a terminal emulation
application connected to the rear panel CONTROL port. Alternatively, ASMi-52 can
be managed from a Telnet host connected to the 10/100BaseT port on the rear
panel.
Configuring Management Parameters
You must define the ASMi-52 internal SNMP agent parameters in order to enable
SNMP and Telnet management (see
Figure
4-1
). You can also enter additional
information about your ASMi-52, such as the name of the contact person detail,
unit location, etc.
³ To access the Management menu:
• From the System Configuration menu, select Management (Main menu >
Configuration > System Configuration > Management).
The Management menu appears (
Figure
4-1
).
ASMi-52
Management
Device Info >
Host IP >
Manager List >
Management Access >
DTS Configuration >
VLAN Encapsulation >
MTU (64 - 1540) ... (1540)
Save
>
ESC-prev.menu; !-main menu; &-exit; @-scroll
Figure
4-1. Management Menu