Specifications
Chapter 7 Application Tutorial Installation and Operation Manual
7-8 Equipment List ASMi-52 Ver. 2.5
2. Select the access level you wish to set: Telnet, SNMP Access, or WEB Access.
3. Select the permission setting for this access level as Enable.
4. Press <S> to save the changes.
The changes are saved in the unit.
Configuring Terminal Parameters
The terminal is connected to the control port. The management software allows
you to configure the terminal baud rate.
The Baud Rate parameter is masked during a Telnet session.
³ To change the terminal baud rate:
1. Select Main Menu> Configuration> System> Terminal.
The Terminal screen appears.
LRS-16
Configuration>System>Terminal
1. Baud rate > (9600 bps)
>
ESC-Previous menu; !-Main menu; &-Exit 1M/ 1C
Figure
7-11. Terminal Screen
2. Select Baud rate.
The Baud Rate screen appears.
LRS-16
Configuration>System>Terminal>Baud rate (9600 bps)
1. 9600 bps
2. 19200 bps
3. 38400 bps
4. 57600 bps
5. 115200 bps
>
ESC-Previous menu; !-Main menu; &-Exit 1M/ 1C
Figure
7-12. Baud Rate Screen
3. Select the desired baud rate (9600, 19200, 38400, 57600, or 115200).
The default baud rate is 9600.
4. Return to the Terminal screen and press <S> to save the changes.
The changes are saved in the unit.