ASMi-52 Ver. 2.8 Performing Diagnostic Tests 5-17
5.4 Troubleshooting
Use the chart shown in
Table
5-6
to identify and remedy problems in unit
operation.
Table
5-6. Troubleshooting Chart
Fault Probable Cause Remedial Action
Power led off No power supplied to unit • Check power source.
• Check power cable connected and
correctly wired.
Ethernet Link Led off • No Ethernet Link detected
• Ethernet ports of the ASMi-52
and user equipment are not in
the same rate or duplex mode
• Check cable connected and
correctly wired.
• Check the user’s and ASMi-52
Ethernet port configuration
(negotiation, rate, duplex mode).
• Use Event Log File to check events.
No traffic flow between two
units
Configuration or logical layer
problems
• Use System Interface Status screen
for assistance. All active ports that
show Activation–Up, should show
Operation–Up.
• Use Event Log File to check events.
• Check the ASMi-52 configuration
and, if necessary, other ASMi-52
parameters.
Partial Traffic Flow Timing configuration is not
properly set
• Check timing settings.
5.5 Performing Diagnostic Tests
The user-controlled test functions of ASMi-52 consist of the loopback tests and
LEDs test. The purpose of these tests is to determine the source of a break in
the data flow.
•
Both local and remote ASMi-52 units must be configured and synchronized
properly to allow remote loopback activation.
•
Only one loopback can be activated at a time, either on the local or remote
unit.
Note