Installation and Operation Manual Chapter 5 Monitoring and Diagnostics
ASMi-52 Ver. 2.8 Performing Diagnostic Tests 5-17
5.4 Troubleshooting
Use the chart shown in
Table
5-6
to identify and remedy problems in unit
operation.
Table
5-6. Troubleshooting Chart
Fault Probable Cause Remedial Action
Power led off No power supplied to unit Check power source.
Check power cable connected and
correctly wired.
Ethernet Link Led off No Ethernet Link detected
Ethernet ports of the ASMi-52
and user equipment are not in
the same rate or duplex mode
Check cable connected and
correctly wired.
Check the user’s and ASMi-52
Ethernet port configuration
(negotiation, rate, duplex mode).
Use Event Log File to check events.
No traffic flow between two
units
Configuration or logical layer
problems
Use System Interface Status screen
for assistance. All active ports that
show Activation–Up, should show
Operation–Up.
Use Event Log File to check events.
Check the ASMi-52 configuration
and, if necessary, other ASMi-52
parameters.
Partial Traffic Flow Timing configuration is not
properly set
Check timing settings.
5.5 Performing Diagnostic Tests
The user-controlled test functions of ASMi-52 consist of the loopback tests and
LEDs test. The purpose of these tests is to determine the source of a break in
the data flow.
Both local and remote ASMi-52 units must be configured and synchronized
properly to allow remote loopback activation.
Only one loopback can be activated at a time, either on the local or remote
unit.
Note