Specifications

Chapter 5 Monitoring and Diagnostics Installation and Operation Manual
5-16 Handling Events ASMi-52 Ver. 2.8
Handling Traps
ASMi-52 supports SNMP traps for the following events:
Cold start
Warm start
Link up
Link down
Authentication failure
TFTP status change
Agent status change
Modem Rack Alarm
The list of traps is given in
Table
5-5
.
Table
5-5. Trap List
Trap Description OID
coldStart The unit has been restarted (powered up),
and successfully completed the cold-start
process
1.3.6.1.6.3.1.1.5.1
coldStart The unit ASMi-52 has been restarted and
successfully completed the warm-start
process
1.3.6.1.6.3.1.1.5.2
authenticationFailure User authentication has failed 1.3.6.1.6.3.1.1.5.5
linkDown An uplink, tributary or user port has been
disconnected
1.3.6.1.6.3.1.1.5.3
linkUp An uplink, tributary or user port has been
connected
1.3.6.1.6.3.1.1.5.4
rad.tftpStatusChangeTrap TFTP session status has changed 1.3.6.1.4.1.164.6.1.0.1
rad.agnStatusChangeTrap SNMP agent status has changed 1.3.6.1.4.1.164.6.1.0.2
rad.modmRackAlarm An alarm occurred in the system 1.3.6.1.4.1.164.3.4.0.14