Specifications

Installation and Operation Manual Chapter 5 Monitoring and Diagnostics
ASMi-52 Ver. 2.8 Handling Events 5-15
Terminal Message Description
GS CRC ERROR DETECT More than three SHDSL CRC errors were detected during the last
second
REP SEGD ERROR DETECT SEGD error from repeater: sync fail on another part of the span
TRAINING MODE STACK CPE Training state timeout is exceeded (3 min)
DEVICE PRIMARY CALL FAIL The primary number dial attempt has failed
DEVICE DIAL CALL FAIL The dial out call cycle has failed
Working with the Port Log File
ASMi-52 maintains a port alarm buffer, which can store up to 100 alarm
messages. The port log file specifies alarm or event name, severity (major or
minor), status (ON or OFF), and time elapsed since the last ASMi-52 reset.
³ To display the log file:
From the Physical Port Status menu, select Port Log File (Main menu >
Monitoring > Physical Ports Status > Port Log File).
The Log File screen appears (see
Figure
5-15
).
ASMI 52
Port log file
Source Name Severity Status Time
1. Local MNGMNT IS DOWN MAJOR ON 0:00:00
2. Local E1 SYNC LOSS LINE A MAJOR ON 0:00:00
3. Local E1 SIGNAL LOSS MAJOR ON 0:00:00
4. Local SYNC LOSS LINE A MAJOR ON 0:00:00
5. Local E1 SYNC LOSS MAJOR OFF 0:11:48
6. Local E1 SIGNAL LOSS MAJOR OFF 0:11:48
7. Local SYNC LOSS LINE A MAJOR OFF 0:23:22
8. Local MNGMNT IS DOWN MAJOR OFF 0:24:25
9. Remote LAN NOT CONNECTED MAJOR ON 0:24:29
ESC-prev. menu; !-main menu; &-exit; @-scroll; ?-help
1 user(s)
Figure
5-15. Port Log File Screen
³ To clear the log file:
1. From the Physical Port Status menu, select Port Clear Log File (Main menu >
Monitoring > Physical Port Status > Port Clear Log File) to clear the log file.
A confirmation message is displayed at the bottom of the screen.
2. Type Y and press <Enter>.
All the log file entries are deleted from the log file.