Specifications
Chapter 4 Configuration Installation and Operation Manual
4-48 Performing Additional Tasks ASMi-52 Ver. 2.8
ASMi-52
Factory default
Remote unit number (1)
Local factory default ...
Remote factory default ...
Local factory default W/O MNG ...
Remote factory default W/O MNG ...
>
ESC - prev. menu ; ! – main menu ; & – exit
Figure
4-49. Factory Default Menu
2. From the Factory Default menu, perform one of the following steps:
Select Local Factory Default to reset the local ASMi-52.
Select Remote Factory Default to reset the remote device.
Select Local Factory Default W/O MNG to reset all parameters, except for
the IP address, mask, default gateway and the manager list of the local
ASMi-52.
Select Remote Factory Default W/O MNG to reset all parameters, except
for the IP address, mask, default gateway and the manager list of the
remote ASMi-52.
•
Local/Remote Factory Default W/O MNG parameters are available only for the
units equipped with the management LAN port.
ASMi-52 displays the following message:
Request to factory default !!! Confirm Y/N
3. Type Y to confirm the reset.
ASMi-52 resets all configuration parameters, except for the master clock
(and IP values), to their default settings and restarts the system.
Resetting the ASMi-52 Modem
You can reset the SHDSL interface of the modem or repeater, or perform the
overall reset of the modem.
³ To reset the SHDSL interface or perform the overall device reset:
1. From the System Configuration menu, select Reset.
The Reset menu appears (see
Figure
4-50
).
2. From the Reset menu, select Local Reset to reset the local modem or Remote
Reset to reset the remote device.
The Local/Remote Reset menu appears (see
Figure
4-51
).
3. From the Local/Remote Reset menu, select Local/Remote Device Reset to
perform the overall reset or select Local/Remote SHDSL Line Reset to reset
the SHDSL interface.
A confirmation message appears.
Note